ST 108 testing requirements

Contact us for tables of test guidelines and frequency.

The testing requirements for ANSI/AAMI ST108:2023, which covers water for the processing of medical devices, include several key aspects. These requirements ensure that the water used in medical device processing meets the necessary standards for safety and effectiveness. Here are some of the testing requirements outlined in the standard:

1. Microbiological Testing: This testing involves evaluating the water for the presence of microorganisms, such as bacteria, viruses, and fungi. It includes tests for total viable count, specific pathogens, and endotoxins.

2. Chemical Testing: Chemical testing is performed to assess the presence of various impurities and contaminants in the water. This may include testing for heavy metals, organic compounds, residual disinfectants, and other chemical substances that could potentially impact the quality of the water.

3. Conductivity and pH Testing: These tests determine the electrical conductivity and pH level of the water. Conductivity is measured to ensure the absence of excessive mineral content, while pH testing helps evaluate the water’s acidity or alkalinity.

4. Total Organic Carbon (TOC) Testing: TOC testing measures the amount of organic carbon present in the water. This test is crucial in assessing the overall quality and purity of the water, as high levels of organic carbon can indicate the presence of organic contaminants.

5. Particulate Matter Testing: This testing involves analyzing the water for the presence of particulate matter, such as sediment, debris, or other solid particles. It helps ensure that the water is free from any visible impurities that could potentially affect the medical device processing.

6. Validation of Water System: The standard also requires the validation of the water system used for medical device processing. This involves conducting various tests, such as system performance qualification (SPQ), to verify the effectiveness and reliability of the water treatment and distribution system.

It is important to note that these testing requirements are just a summary of the key aspects outlined in the ANSI/AAMI ST108:2023 standard. The complete standard provides detailed guidelines and procedures for conducting the necessary tests to ensure the quality and safety of water used in the processing of medical devices.